<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>10024</ErrorNumber>
<ErrorFamily>Hardware</ErrorFamily>
<ErrorMessage>
HARDWARE: Card cage over temp
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The SGE's temperature sensor has been triggered, presumably by a dangerously high card cage
temperature.  As a safety precaution, a number of the recorder's power supplies have been disabled.  The
card cage fans may be faulty or their airflow is restricted
</text></DescriptionText>
<DescriptionText><text>
Check the temperature of the card cage.  If it seems abnormally high, the card cage fans may be faulty or
their airflow is restricted.  If the card cage temperature seems normal, check that the SGE is seated properly
in the card cage.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Turn the platesetter off. Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
Card cage fan(s) faulty
</Cause>
<Cause>
Card cage airflow restricted
</Cause>
<Cause>
SGE not properly seated.
</Cause>
<Cause>
SGE temperature sensor faulty
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:30 2008 PST
</Updated>
<Links>
</Links>
</Error>